XLPE Enfundado Bajo Voltaje ABC Antena Incluido Cable Eléctrico, Cable de Alimentación
XLPE Enfundado Bajo Voltaje ABC Antena Incluido Cable Eléctrico, Cable de Alimentación image
Get Latest Price Request a quote
Información Básica
CE
Información Adicional
Descripción de Producto
XLPE enfundado Bajo voltaje ABC Antena incluido Cable eléctrico, cable de alimentación
(1)autosuficiente
| La fase | La fase | La fase | Diámetro total aprox. | Max. D.C. la resistencia del conductor a 20ºC | |||
| AAC+UV-XLPE | Conductor compacto | Los rayos UV aislamiento XLPE | |||||
| No.X Sección transversal de la Normal de núcleos | Nº de hilos al. | Diámetro total | Espesor normal | Min. | De diámetro | ||
| N° x mm2 | – | Mm | Mm | Mm | Mm | Mm | Ohm/km. |
| 1 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 6.05 | 3.08 |
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.20 | 1.91 |
| 1 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 8.40 | 1.20 |
| 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 9.80 | 0.868 |
| 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 11.10 | 0.641 |
| 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 12.60 | 0.443 |
| 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 14.80 | 0.320 |
| 1 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 16,20 | 0.253 |
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.20 | 0.206 |
| 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 20,20 | 0.164 |
| 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 22.80 | 0,125 |
| 2 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 12.10 | 3.08 |
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14,40 | 1.91 |
| 2 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 16,80 | 1.20 |
| 2 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 19,60 | 0.868 |
| 2 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 22,20 | 0.641 |
| 2 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 25.20 | 0.443 |
| 2 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 29.60 | 0.320 |
| 2 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 32,40 | 0.253 |
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.40 | 0.206 |
| 2 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 40.40 | 0.164 |
| 2 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 45.60 | 0,125 |
| 3 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 13,07 | 3.08 |
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 1.91 |
| 3 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 18.14 | 1.20 |
| 3 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 21.17 | 0.868 |
| 3 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 23,98 | 0.641 |
| 3 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 27.22 | 0.443 |
| 3 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 31.97 | 0.320 |
| 3 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 34.99 | 0.253 |
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 0.206 |
| 3 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 43.63 | 0.164 |
| 3 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 49.25 | 0,125 |
| 4 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 14.64 | 3.08 |
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 1.91 |
| 4 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 20,33 | 1.20 |
| 4 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 23.72 | 0.868 |
| 4 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 26.86 | 0.641 |
| 4 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 30.49 | 0.443 |
| 4 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 35.82 | 0.320 |
| 4 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 39.20 | 0.253 |
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 0.206 |
| 4 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 48.88 | 0.164 |
| 4 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 55.18 | 0,125 |
(2) fase + neutro
| La fase | Punto muerto | La fase | Punto muerto | Diámetro total aprox. | Max. D.C. la resistencia del conductor a 20ºC | ||||
| AAC+UV-XLPE | AAAC | Conductor compacto | Los rayos UV aislamiento XLPE | Conductor | |||||
| La fase | Punto muerto | ||||||||
| No.X Sección transversal de la Normal de núcleos | No.X Sección transversal de la Normal de núcleos | No.de al cable. | En general de dia. | Espesor normal | Min. | N/Dia de Al Alambre de aleación. | |||
| N° x mm2 | N° x mm2 | – | Mm | Mm | Min. | N/mm | Mm | Ohm/km. | Ohm/km. |
| 1 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.30 | 1.91 | 2.217 |
| 1 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 14,70 | 1.20 | 1.393 |
| 1 X 35 | 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 7/2.50 | 17.30 | 0.868 | 1.007 |
| 1 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.10 | 0.641 | 0.744 |
| 1 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.10 | 0.443 | 0.514 |
| 1 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.30 | 0.320 | 0.371 |
| 1 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2,80 | 30.20 | 0.253 | 0,294 |
| 1 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
| 1 X 185 | 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 37/2.50 | 37.70 | 0.164 | 0.190 |
| 1 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0,125 | 0,145 |
| 2 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
| 2 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 16,63 | 1.20 | 1.393 |
| 2 X 35 | 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 7/2.50 | 19,51 | 0.868 | 1.007 |
| 2 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
| 2 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25,70 | 0.443 | 0.514 |
| 2 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.320 | 0.371 |
| 2 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2,80 | 33.41 | 0.253 | 0,294 |
| 2 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
| 2 X 185 | 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 37/2.50 | 41.69 | 0.164 | 0.190 |
| 2 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0,125 | 0,145 |
| 3 X 16 | 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
| 3 X 25 | 1 X 25 | 7 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.20 | 1.393 |
| 3 X 35 | 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
| 3 X 50 | 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
| 3 X 70 | 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
| 3 X 95 | 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.320 | 0.371 |
| 3 X 120 | 1 X 120 | 19 | 13 | 1.6 | 1.34 | 19/2,80 | 37.87 | 0.253 | 0,294 |
| 3 X 150 | 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
| 3 X 185 | 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 37/2.50 | 47.25 | 0.164 | 0.190 |
| 3 X 240 | 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0,125 | 0,145 |
(3) fase + neutro + Servicio de conexión
| La fase | Punto muerto | La conexión del servicio | La fase | Punto muerto | La conexión del servicio | Aprox.Diámetro total del cable incluido | |||||
| AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Conductor | La radiación UV-XLPE | Conductor | La radiación UV-XLPE | Conductor compacto | La radiación UV-XLPE | |||
| No.X Sección transversal de la Normal de núcleos | No.X Sección transversal de la Normal de núcleos | No.X Sección transversal de la Normal de núcleos | Nº de Al. El cable | En general de dia. | Lo normal Grosor |
N/diámetro de Al. El cable | Lo normal Grosor |
Nº de Al. El cable | En general de dia. | Lo normal Grosor |
|
| N° x mm2 | N° x mm2 | N° x mm2 | – | Mm | Mm | Mm | Mm | N/mm | Mm | Mm | Mm |
| 3 X 16 | 1 X 50 | 1 X 16 | 7 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 26.2 |
| 3 X 25 | 1 X 50 | 1 X 16 | 7 | 6 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 28.6 |
| 3 X 35 | 1 X 50 | 1 X 16 | 7 | 7.0 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 31.4 |
| 3 X 50 | 1 X 50 | 1 X 16 | 7 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 34 |
| 3 X 70 | 1 X 50 | 1 X 16 | 19 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 37 |
| 3 X 95 | 1 X 50 | 1 X 16 | 19 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 41.4 |
| 3 X 120 | 1 X 50 | 1 X 16 | 19 | 13 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 44.2 |
| 3 X 16 | 1 X 50 | 2 X 16 | 7 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 26.2 |
| 3 X 25 | 1 X 50 | 2 X 16 | 7 | 6 | 1.2 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 28.6 |
| 3 X 35 | 1 X 50 | 2 X 16 | 7 | 7.0 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 31.4 |
| 3 X 50 | 1 X 50 | 2 X 16 | 7 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 34 |
| 3 X 70 | 1 X 50 | 2 X 16 | 19 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 37 |
| 3 X 95 | 1 X 50 | 2 X 16 | 19 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 41.4 |
| 3 X 120 | 1 X 50 | 2 X 16 | 19 | 13 | 1.6 | 7/3.0 | 1.4 | 7 | 4.8 | 1.2 | 44.2 |
Nosotros somos China XLPE Enfundado Bajo Voltaje ABC Antena Incluido Cable Eléctrico, Cable de Alimentación fabricante y proveedor,Puede obtener más detalles con el correo electrónico, obtendrá un precio económico o un precio de fábrica.
Get Latest Price Request a quote
Popular Cable de alimentación Productos
El cable eléctrico Cable Flexible de alarma a prueba de fuego Cable nominal
Aleación de aluminio corrugado XLPE eléctrico revestimiento de cobre flexible Cable minero mina Lsoh
Núcleo de cobre aislados con PVC blindado Metro cable de alimentación eléctrica
Cable de instalación de la luz de baja tensión Xmvk 3x2.5, 5X2.5mm2
Fase 4 del Metro cable eléctrico de 150mm2 de 300mm2 Yjv22 Cable de alimentación de cobre XLPE
Popular Cable de antena Productos
NFC 33-209 los cables de antena integrado+54.6 3X70+1x16 Cable ABC
Lxs Twisted Cable de antena de techo aluminio 0.6/1kv+54.6 3X70+2x16, 4x25mm2
0.6/1kv de núcleo de aluminio PVC, aislamiento XLPE Paquete de antena de cable ABC
6 AWG aislamiento XLPE Cable ABC
ABC Quadruplex de cable Cable 3*70+70mm2
Sobrecarga de cobre y aluminio con aislamiento de conductores del cable de antena
Popular jpcable99 Productos
Vendedor caliente medio Voltaje Cable de alimentación de blindados aislamiento XLPE
Cable de alimentación pirorretardante aislado de PVC con núcleo de cobre
6 / 10kv Cable Conductor de Cobre Cable Eléctrico Cable de Alimentación XLPE
35mm2 Cable de alimentación aislado con PVC
Conductor de cobre, cable de alimentación de aislamiento XLPE con buena calidad y precio.
Conductores ACSR Liebre (conductores de aluminio reforzado de acero) -BS 215
Popular Paquete de antena de baja tensión de cable Productos
ABC de baja tensión incluye antena de cable de alimentación
Tags: Cable de alimentación, Cable de antena, jpcable99, Paquete de antena de baja tensión de cable, XLPE Enfundado Bajo Voltaje ABC Antena Incluido Cable Eléctrico