Cable aislado techo / Servicio de Cable caída / ABC Cable de 4X95sqmm
Cable aislado techo / Servicio de Cable caída / ABC Cable de 4X95sqmm image
Get Latest Price Request a quote
Información Básica
CE ,
CCC ,
VDE
Información Adicional
Descripción de Producto
| La fase | La fase | La fase | Diámetro total aprox. | Max. D.C. la resistencia del conductor a 20 grados centígrados | |||
| AAC+UV-XLPE | Conductor compacto | Los rayos UV aislamiento XLPE | |||||
| No.X Sección transversal de la Normal de núcleos | Nº de hilos al. | Diámetro total | Espesor normal | Min. | De diámetro | ||
| N° X mm 2 | – | Mm | Mm | Mm | Mm | Mm | Ohm/km. |
| 1 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 6.05 | 3.08 |
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.20 | 1.91 |
| 1 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 8.40 | 1.20 |
| 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 9.80 | 0.868 |
| 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 11.10 | 0.641 |
| 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 12.60 | 0.443 |
| 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 14.80 | 0.320 |
| 1 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 16,20 | 0.253 |
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.20 | 0.206 |
| 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 20,20 | 0.164 |
| 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 22.80 | 0,125 |
| 2 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 12.10 | 3.08 |
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14,40 | 1.91 |
| 2 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 16,80 | 1.20 |
| 2 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 19,60 | 0.868 |
| 2 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 22,20 | 0.641 |
| 2 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 25.20 | 0.443 |
| 2 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 29.60 | 0.320 |
| 2 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 32,40 | 0.253 |
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.40 | 0.206 |
| 2 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 40.40 | 0.164 |
| 2 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 45.60 | 0,125 |
| 3 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 13,07 | 3.08 |
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 1.91 |
| 3 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 18.14 | 1.20 |
| 3 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 21.17 | 0.868 |
| 3 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 23,98 | 0.641 |
| 3 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 27.22 | 0.443 |
| 3 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 31.97 | 0.320 |
| 3 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 34.99 | 0.253 |
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 0.206 |
| 3 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 43.63 | 0.164 |
| 3 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 49.25 | 0,125 |
| 4 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 14.64 | 3.08 |
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 1.91 |
| 4 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 20,33 | 1.20 |
| 4 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 23.72 | 0.868 |
| 4 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1. | 26.86 | 0.641 |
| 4 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 30.49 | 0.443 |
| 4 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 35.82 | 0.320 |
| 4 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 39.20 | 0.253 |
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 0.206 |
| 4 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 48.88 | 0.164 |
| 4 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 55.18 | 0,125 |
Embalaje y envío
Nosotros somos China Cable aislado techo / Servicio de Cable caída / ABC Cable de 4X95sqmm fabricante y proveedor,Puede obtener más detalles con el correo electrónico, obtendrá un precio económico o un precio de fábrica.
Get Latest Price Request a quote
Popular ABC Productos
El conductor del cable de aluminio 16mm2 aislada 0.6/1kV XLPE AISLADO
2/0 AWG Quadplex Incluye antena de cable ABC
Sobrecarga ABC Cable con AAC/ACSR/AAAC Messager Neutral
Al/0.6/1kv XLPE sobrecarga Cable ABC
La BS 7870-5 0.6/1 Kv ABC la antena de cable Cable incluido fabricante
ABC, el Paquete de cable de antena de cable de antena, cable ramificado
Popular Cable aislado techo / Servicio de Cable caída / ABC Cable de 4X95sqmm Productos
Popular El cable Productos
Mv-90 XLPE Metro Cable de aluminio
Muticore Conductor de cobre o aluminio Cable concéntrico XLPE
Conductor de cobre de Tw Construcción Thw cable de la casa
La norma IEC 4*50mm2/AAC AAAC Cable eléctrico/ACSR conductores Cable ABC
ASTM Conductor de aluminio reforzado de acero Swan 4AWG conductores ACSR desnuda
CSA Urd 33kv de tensión de medio metro Cable de alimentación
Popular zzjinshui Productos
De 3 Núcleos de cable flexible de 4 mm.
AAAC Roble Conductor 100mm2 estándar BS
La norma ASTM AAAC Conductor de aleación de aluminio 100mm2
Los cables eléctricos para la venta Sudáfrica
AAC Todos los conductores de aluminio, parte 2 la norma ASTM B231 Unidad Inch-Pound
Aislamiento de PVC cables eléctricos/edificio de la casa de alambre, cable
Tags: ABC, Cable aislado techo / Servicio de Cable caída / ABC Cable de 4X95sqmm, El cable, zzjinshui