ACSR Conductor de aluminio reforzado de acero Antena Cable de paquete de Gastos Generales ABC
ACSR Conductor de aluminio reforzado de acero Antena Cable de paquete de Gastos Generales ABC image
Get Latest Price Request a quote
Información Básica
CCC
Información Adicional
Descripción de Producto
DescripcióN de producto
ACSR Conductor de aluminio de la antena de cable de acero reforzado Paquete
1.La especificacióN
JL Todos los conductores de aluminio paráMetro báSico | ||
La especificacióN | DiáMetro exterior del cable | Peso aprox. |
10 | 4.05 | 27,95 |
16 | 5.13 | 45.00 |
25 | 6.39 | 69.59 |
35 | 7.50 | 96.14 |
40 | 8.10 | 112.08 |
50 | 9.00 | 138.35 |
63 | 10.20 | 176.64 |
70 | 10.80 | 199.28 |
95 | 12,50 | 265.80 |
100 | 13.0 | 279.49 |
120 | 14.3 | 338.18 |
125 | 14.5 | 349.36 |
150 | 15.8 | 413.65 |
160 | 16.4 | 447.18 |
185 | 17.5 | 511.47 |
200 | 18.3 | 558.98 |
210 | 18.8 | 586.93 |
240 | 20.0 | 667.98 |
250 | 20.5 | 698.73 |
300 | 22.4 | 832.88 |
315 | 23.0 | 880.39 |
400 | 26.0 | 1117.96 |
450 | 27.6 | 1260.50 |
500 | 29.1 | 1405.84 |
560 | 30.7 | 1565.15 |
630 | 32.7 | 1763.58 |
710 | 34.7 | 1984.38 |
800 | 36.8 | 2238.72 |
JL/G1A JL/G2A JL/G3A JL1/G1A JL1/G2A JL1/G3A JL2/G1A JL2/G2A JL2/G3A &JL3/G1A JL3/G2A JL3/G3A El conductor de aluminio reforzado de acero paráMetro báSico |
|||||
La especificacióN | DiáMetro exterior del cable | Peso aprox. | La especificacióN | DiáMetro exterior del cable | Peso aprox. |
10/2 | 4.50 | 43.68 | 240/30 | 21.6 | 932.18 |
16/3 | 5.55 | 66.23 | 240/40 | 21.7 | 975.04 |
25/4 | 6.90 | 102.35 | 240/55 | 22.4 | 1117.98 |
35/6 | 8.16 | 143.40 | 250/25 | 21.5 | 892.12 |
40/6 | 8.73 | 164.01 | 250/40 | 22.2 | 1020.00 |
50/8 | 9,60 | 198.46 | 300/15 | 23.0 | 950.86 |
50/30 | 11.6 | 375.35 | 300/20 | 23.1 | 995.25 |
65/10 | 11.0 | 259.24 | 300/25 | 23.8 | 1069.16 |
70/10 | 11.4 | 279.25 | 300/40 | 23.9 | 1145.53 |
70/40 | 13.6 | 516.07 | 300/50 | 24.3 | 1223.68 |
95/15 | 13.6 | 384.61 | 300/70 | 25.2 | 1415.26 |
95/20 | 13.9 | 414.19 | 315/22 | 23.9 | 1055.27 |
95/55 | 16.0 | 714.12 | 400/20 | 26.9 | 1299.71 |
100/17 | 13.8 | 411.31 | 400/25 | 26.6 | 1309.52 |
120/7 | 14.5 | 384.69 | 400/35 | 26.8 | 1364.35 |
120/20 | 15.1. | 472.61 | 400/50 | 27.6 | 1526.85 |
120/25 | 15.7 | 532.00 | 400/65 | 28.0 | 1629.04 |
120/70 | 18.0 | 903.79 | 400/95 | 29.1 | 1876.79 |
125/7 | 14.9 | 404.07 | 450/30 | 28.6 | 1503.20 |
125/20 | 15.6 | 588.54 | 450/60 | 29.3 | 1721.49 |
150/8 | 16.0 | 468.73 | 500/35 | 30.1 | 1670.57 |
150/20 | 16.7 | 556.46 | 500/45 | 30.0 | 1706.92 |
150/25 | 17.1 | 607.47 | 500/65 | 30.9 | 1905.37 |
150/35 | 17.5 | 682.39 | 560/40 | 31.8 | 1869.84 |
160/9 | 16.8 | 517.20 | 560/70 | 32.7 | 2122.01 |
185/10 | 18.0 | 591.98 | 630/45 | 33.8 | 2100.58 |
185/25 | 18.9 | 713.67 | 630/55 | 34.3 | 2233.15 |
185/30 | 18.9 | 739.53 | 630/80 | 34.7 | 2386.32 |
185/45 | 19.6 | 857.27 | 710/50 | El 35,9 | 2369.95 |
200/11 | 18.8 | 646.60 | 710/90 | 36.8 | 2688.85 |
210/10 | 19.0 | 659.36 | 720/50 | 36.2 | 2421.77 |
210/25 | 20.0 | 798.05 | 800/55 | 38.4 | 2719.46 |
210/35 | 20.4 | 864.06 | 800/70 | 38.6 | 2821.09 |
210/50 | 20.9 | 969.34 | 800/100 | 39.1 | 3038.27 |
Todo conductor de aleacióN de aluminio paráMetro báSico | |||||
JLHA1 JLHA2 | JLHA3 JLHA4 | ||||
La especificacióN | DiáMetro exterior del cable | Peso aprox. | La especificacióN | DiáMetro exterior del cable | Peso aprox. |
16 | 5.13 | 45,11 | 25 | 6.39 | 69.77 |
20 | 5.49 | 51.56 | 35 | 7.50 | 96.39 |
25 | 6.39 | 69.77 | 40 | 8.10 | 112.37 |
30 | 6.87 | 80.70 | 50 | 9.00 | 138.71 |
35 | 7,56 | 97.79 | 70 | 10.8 | 199.79 |
45 | 8,67 | 128.62 | 95 | 12.5 | 266.48 |
50 | 9.06 | 140.39 | 100 | 13.0 | 280.21 |
70 | 10.7 | 196.43 | 120 | 14.3 | 339.06 |
75 | 10.9 | 202.87 | 125 | 14.5 | 350.27 |
95 | 12.5 | 266.48 | 150 | 15.8 | 414.72 |
120 | 13.9 | 322.25 | 185 | 17.5 | 512.79 |
145 | 15.5 | 400.71 | 200 | 18.3 | 560.43 |
150 | 15.9 | 420.32 | 210 | 18.8 | 588.45 |
185 | 17.6 | 515.59 | 240 | 20.0 | 669.71 |
210 | 18.8 | 588.45 | 250 | 20.5 | 700.54 |
230 | 19.7 | 644.49 | 275 | 21.6 | 773.39 |
240 | 20.1 | 672.51 | 280 | 21.7 | 781.80 |
300 | 22.5 | 837.84 | 300 | 22.4 | 835.04 |
360 | 24.7 | 1014.37 | 315 | 23.0 | 882.67 |
400 | 26.0 | 1120.86 | 335 | 23.8 | 941.52 |
465 | 27.9 | 1288.98 | 340 | 23.9 | 952.73 |
500 | 29.1 | 1401.07 | 400 | 26.0 | 1120.86 |
520 | 29.5 | 1451.51 | 425 | 26.8 | 1193.71 |
580 | 31.2 | 1611.23 | 450 | 27.6 | 1263.77 |
630 | 32.7 | 1768.15 | 500 | 29.1 | 1409.48 |
650 | 33.0 | 1807.38 | 530 | 30.0 | 1487.94 |
720. | 35.0 | 2031.55 | 560 | 30.7 | 1569.20 |
800 | 36.8 | 2244.51 | 630 | 32.7 | 1768.15 |
675 | 33.8 | 1888.64 | |||
710 | 34.7 | 1989.52 | |||
800 | 36.8 | 2244.51 |
JL(JL1,JL2,JL3)/LHA1 El conductor de aluminio reforzado de aleacióN de paráMetro báSico |
||
La especificacióN | DiáMetro exterior del cable | Peso aprox. |
25/20 | 8.34 | 118.92 |
40/30 | 10.5 | 187.47 |
60/45 | 13.2 | 297.71 |
80/50 | 14.9 | 368.16 |
105/60 | 16.8 | 470.27 |
130/140 | 21.4 | 758.42 |
135/80 | 18.9 | 593.36 |
135/140 | 21.6 | 772.42 |
135/145 | 21.7 | 780.81 |
165/170 | 23.8 | 940.34 |
165/175 | 23.9 | 951.53 |
170/95 | 211. | 739.68 |
210/220 | 26.8 | 1192.21 |
210/230 | 27.6 | 1262.18 |
235/250 | 28.7 | 1368.52 |
260/275 | 30.2 | 1516.85 |
265/60 | 23.4 | 906.83 |
270/420 | 34.2 | 1937.11 |
307/470 | 36.3 | 2177.85 |
335/80 | 26.4 | 1155.14 |
345/530 | 38.5 | 2454.98 |
365/165 | 30.0 | 1485.29 |
375/85 | 27.9 | 1293.28 |
415/95 | 29.5 | 1441.20 |
455/205 | 33.5 | 1854.52 |
465/110 | 31.2 | 1616.24 |
465/210 | 33.8 | 1885.28 |
505/65 | 31.1 | 1594.69 |
515/230 | 35.6 | 2092.27 |
535/240 | 36.2 | 2159.39 |
570/390 | 40.3 | 2677.54 |
580/260 | 37.7 | 2352.41 |
630/430 | 42.5 | 2979.70 |
650/295 | 40.0 | 2640.52 |
665/300 | 40.5 | 2710.44 |
705/485 | 45.0 | 3343.43 |
745/335 | 42.8 | 3029.31 |
790/540 | 47.5 | 3732.32 |
800/550 | El 47,9 | 3785.48 |
JLHA3/G1A (G2G3A) ,&JLHA4/G1A (G2G3A) , El conductor de aleacióN de aluminio reforzado de acero paráMetro báSico |
|||||
La especificacióN | DiáMetro exterior del cable | Peso aprox. | La especificacióN | DiáMetro exterior del cable | Peso aprox. |
10/2 | 4.50 | 43,75 | 240/40 | 21.7 | 976.77 |
16/3 | 5.55 | 66.35 | 240/55 | 22.4 | 1119.73 |
35/6 | 8.16 | 143.66 | 300/15 | 23.0 | 953.01 |
50/8 | 9,60 | 198.81 | 300/20 | 23.4 | 1014.02 |
50/30 | 11.6 | 375.72 | 300/25 | 23.8 | 1071.37 |
70/10 | 11.4 | 279.74 | 300/40 | 23.9 | 1147.70 |
70/40 | 13.6 | 516.58 | 300/50 | 24.3 | 1225.85 |
95/15 | 13.6 | 385.29 | 300/70 | 25.2 | 1417.47 |
95/20 | 13.9 | 414.88 | 400/20 | 26.9 | 1302.65 |
95/55 | 16.0 | 714.82 | 400/25 | 26.6 | 1312.36 |
120/7 | 14.5 | 385.63 | 400/35 | 26.8 | 1367.18 |
120/20 | 15.1. | 473.45 | 400/50 | 27.6 | 1529.74 |
120/25 | 15.7 | 532.89 | 400/65 | 28.0 | 1631.93 |
120/70 | 18.0 | 904.67 | 400/95 | 29.1 | 1879.75 |
150/8 | 16.0 | 469.77 | 460/60 | 29.8 | 1778.19 |
150/20 | 16.7 | 557.51 | 500/35 | 30.1 | 1674.19 |
150/25 | 17.1 | 608.54 | 500/45 | 30.0 | 1710.46 |
150/35 | 17.5 | 683.45 | 500/65 | 31.0 | 1920.55 |
185/10 | 18.0 | 593.31 | 630/45 | 33.8 | 2105.13 |
185/25 | 18.9 | 715.03 | 630/55 | 34.3 | 2237.78 |
185/30 | 18.9 | 740.84 | 630/80 | 34.5 | 2365.74 |
185/45 | 19.6 | 858.61 | 710/50 | El 35,9 | 2375.08 |
210/10 | 19.0 | 660.83 | 710/90 | 36.8 | 2693.98 |
210/25 | 20.0 | 799.56 | 720/50 | 36.2 | 2427.02 |
210/35 | 20.4 | 865.59 | 800/55 | 38.2 | 2688.92 |
210/50 | 20.9 | 970.85 | 800/70 | 38.6 | 2826.94 |
240/30 | 21.6 | 933.95 | 800/100 | 39.1 | 3041.69 |
2.Nuestra fáBrica
3.Nuestro honor
4.Los datos de contacto
DAN ZHAO | Cable Taifeng Co., Ltd.
Agregar.: Centro de Heda, nº177 Tailiu Road, Shibei Distrito, Qingdao, China
Agregar la fáBrica.: Nº1 Taifeng Road, zona administrativa, Xingtai Dacaozhuang Ciudad, provincia de Hebei, China
Tel: 0086 532 85611663
TeléFono: 17863817629 0086
Sitio web: taifengcable.En.Made-in-china.Com
Nosotros somos China ACSR Conductor de aluminio reforzado de acero Antena Cable de paquete de Gastos Generales ABC fabricante y proveedor,Puede obtener más detalles con el correo electrónico, obtendrá un precio económico o un precio de fábrica.
Get Latest Price Request a quote
Popular ACSR Conductor de aluminio reforzado de acero Antena Cable de paquete de Gastos Generales ABC Productos
Popular Cable de carga Productos
Antena de cable dúplex Paquete
Núcleo de Cobre CC CA Cable de carga del vehículo eléctrico EV
Paquete de antena de cable de 3*70+70mm2+2*16mm2
1KV 10kv 15kv XLPE conductores ACSR AAAC AAC antena cable aislado incluido cable ABC
Los gastos generales de transmisión de potencia eléctrica trenzado XLPE utiliza Cable ABC Aluminio
Servicio de conductores Dropaluminum Quadruplex Neutral-Messenger AAC
Popular El cable eléctrico Productos
Conductor de cobre de retardante de llama XLPE CU/PVC/LV El Cable de alimentación 3x1,5 mm2
Cable de cobre aislados en PVC de 2,0 mm de cable eléctrico Tw Thw 5,5 mm 3,5 mm 8mm 14mm 22mm
Excelente calidad conductores Cable Eléctrico cable trenzado de plata
La construcción de cable Nmd90 300V Cable de cobre de 14/2 con certificado CSA cUL
Popular taifengcable Productos
Cable de la sobrecarga de aleación de aluminio 70mm2 de 95mm2 Cable ABC
Desnudo AAAC Todo conductor de aleación de aluminio Cable Paquete Antena eléctrica aérea
Kvv Kvvp Kvv32 Cable de control de Swa flexible
El cable de 2,5 mm Sq LV 4/7/12/19/C PVC Cu Swa PVC con la interconexión
0.6/1.0kv 4 Core 50/70/95mm blindados XLPE Cable interior o exterior
Cable de alimentación XLPE de alta tensión de 1c*500mm2 de núcleo de aluminio blindada Awa
Tags: ACSR Conductor de aluminio reforzado de acero Antena Cable de paquete de Gastos Generales ABC, Cable de carga, El cable eléctrico, taifengcable